(fungus), we need to pay attention to some things. These are all things we should pay attention to after installing or emptying the water in the water heater. We must (have to) fill the water heater with water first. to turn on the power supply; the filter cotton under the sterilizer box must be replaced before each use; the machine can only be turned on when the water temperature reaches above 61 degree ; Do not open the box lid during the sterilization process. When closing the lid fails, press the lid opening button again and close the lid again; check whether the sterilant is agglomerated before use, and shake the medicine box to separate the medicine into powder before use; Endoscopic instruments without waterproof device (Apparatus) This equipment cannot be used for sterilization; all endoscope lumens must be cleaned, removable parts must be disassembled and sterilized, and instruments with switches must be in the "open" position ( position ); the instruments in the sterilization tray are discharged naturally and neatly, and the connecting hoses and instrument hoses must not be folded (meaning: folding part of the object over), twisted, etc.; during sterilization, the hoses are pressed according to the arc in the tray Place it in the correct shape and do not twist it at will.
When using a medical sterilizer to sterilize instruments (disinfection), the instruments must not be higher than the surface of the disk; after sterilization is completed, if a "sterilization failed" sign is printed, the manufacturer (factory) should be notified for inspection and processing (chǔ lǐ); after sterilization Instruments and articles must be stored in a sterile (meaning: no viable bacteria) environment, and the time between sterilization and use of the instrument should be shortened as much as possible to avoid secondary infection of the instrument; if there is water leakage from the lid, notify the relevant personnel immediately (personnel) Replace the sealing strip on the machine cover; do simple cleaning work (gōng zuò) before starting up and after shutting down the machine every day. Use a dry cloth to dry the moisture in the sterilization tray, and then use 70% alcohol ( (termed ethanol) wipe the inner and outer surfaces (appearance) of the machine cover and close the cover. High-pressure sterilizers, also known as high-pressure steam sterilizers, can be divided into portable sterilizers and vertical high-pressure sterilizers. A device that uses electric heating wires to heat water to generate steam and maintain a certain pressure. It mainly consists of a sealable barrel, pressure gauge, exhaust valve, safety valve, heating wire, etc. The autoclave is suitable for medical and health undertakings, scientific research, agriculture and other units. It is an ideal equipment for sterilizing medical equipment, dressings, glassware, solution culture media, etc. The portable autoclave is a professional inspection equipment certified by QS and HACCP for food factories and drinking water plants. The autoclave series products are rapid and reliable sterilization equipment that use pressure saturated steam to sterilize products. They are suitable for medical use. It is an ideal equipment for health care, scientific research, agriculture and other units to disinfect and sterilize medical equipment, dressings, glassware, solution culture media, etc. When not used for a long time, it will run automatically every 7 days. Perform a comprehensive cleaning and replace the filter element once a month. Discharge the water from the water heater, refill the tank, and run the sterilizer once before use before sterilizing the instrument.

Kirim permintaan
Kategori Produk